|
Electrical & Test Equipment
>>>
Connectors, Switches & Wire
|
NIB!! Andrew/Dryline PMT200A-82015 Dehydrator
| Start Price |
USD 1,250.00 |
| Current Price |
USD 1,250.00 |
| Time Left |
- |
| Bid Count |
0 |
| Buy It Now Price |
- |
| Reserve Price |
- |
| Start Time |
Saturday, August 23, 2008 |
| End Time |
Saturday, August 30, 2008 |
| Location |
Dixon, IL |
|
See more about 'NIB!! Andrew/Dryline PMT200A-82015 Dehydrator'
|
Description
NIB Andrew/Dryline PMT200A-82015 Dehydrator, CTL-Module, 115/220V. Bought 12/05. Never opened. Never Used. The Andrew website shows the wall mount, which I believe this unit is. Tessco shows it as the rack mount. New photo of the unopened box itself. Serious bidder; I can open box to verify. This unit came with a new tower construction package and is surplus. Thanks. **** Last re-listing of this item. There is a non-comm in the area I'll donate this to if it doesn't sell **** The PMT200A is a superior alternativeto bottled nitrogen gas and desiccantdehydrators, especially at remote sites.The unit minimizes the maintenanceassociated with nitrogen tanks andmanually regenerative systems. ThePMT200A uses automatic pressure sensingand microprocessor control to activateand deactivate an air compressor,operating only when needed to maintainpressure in an internal reservoir tank,improving efficiency for reduced wearand maintenance. Power consumption islow: with an auto-detecting ac supply,the PMT200A draws 350–390 wattswhen the compressor is running and<10 watts in idle.The PMT200A features an ElectronicCompressor Control Module that incorporatesprecise pressure sensing withmicroprocessor control circuitry to controlcompressor cycles and provide systemmonitoring.access for maintenance and operational controls. Power,air, and alarm connections of the PMT200A are accessiblefrom the top of the cabinet, when mounted on a wall,cabinet, or on a shelf or floor.Front Mounted Controls and Status Indicators• Digital LCD display for alarm and system status• Dual display modes for system status and last event• Push button power switch with control module• Compressor run-time• Integral 4-port manifold with shut-off valvesStandard Summary AlarmThe PMT200A includes a low-pressure alarm which closesat 1.0 psi (68 mbar), excess run alarm and power failalarm. The standard alarm package provides a singlecontact closure for the three alarms, functioning as a summaryalarm. The PMT200A can be optionally orderedwith an upgraded alarm package. This option adds highhumidity alarm (> 7.5% RH) plus individual contacts for allfour alarms. excess run alarm (user adjustable) and powerfail alarm. An approved terminal block is provided for thealarm outputs.Electrical ConnectionsUnits designed for use throughout the world. The AC inputis auto detecting for 115/230 Vac and the compressor israted for both 50 and 60 Hz operation. Units are availableeither with a UL/CSA cord set or with a CE harmonizedcord with stripped leads for attachment of a localcountry plug.4-Port DistributionDry air distribution is incorporated into the basic dehydratordesign. Shut-off valves control a 4-port manifold functionthat splits the air stream into four independent outputs.Bulkhead compression fittings are supplied on the cabinetthat accept 3/8-inch polytubing to connect to the transmissionline.Expansion OptionsManifold, 2-Port, 0-15 lb/in2 6600D-2Manifold, 4-Port, 0-15 lb/in2 6600D-4Manifold, 6-Port, 0-15 lb/in2 6600D-6Line Monitor, 4-port LM400Low Pressure OptionLow Pressure Regulator, 0-2 psi, AE01A-D1339-002SpecificationsOutput Pressure . . . . . . . . . . . . . . . . . . .350 mbar/35 kPa (5 psi). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .factory set, continuousOutput Flow Rate . . . . . . . . . . . . . . . . . .5.66 SLPM (0.2 SCFM)Output Dew Point . . . . . . . . . . . . . . . . .better than -45°C (-50°F) at. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92% RH at +40°C (104°F)Operating Temperature . . . . . . . . . . . . .+1°C to +40°C (+33°F to. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .+104°F)Low Pressure Alarm . . . . . . . . . . . . . . . .68 mbar/7 kPa (1 psi)High Humidity Alarm . . . . . . . . . . . . .7.5% RH, factory set (Optional)Excess Run Alarm . . . . . . . . . . . . . . . . .10 minutes, factory setPower Fail Alarm . . . . . . . . . . . . . . . . .loss of input power, factory setAlarm Contact Rating . . . . . . . . . . . . . .Form “C’ dry contacts, 2 amps @ 30 VdcInput Power . . . . . . . . . . . . . . . . . . . . . .115/230 Vac, 50/60 Hz, Auto detectingOutput Air Connectors (4) . . . . . . . . . . .compression fitting 3/8¬inch polyethylene. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .tubingDimensions . . . . . . . . . . . . . . . . . . . . .height 457 mm (18 in). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .width 445 mm (17.5 in). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .depth 178 mm (7 in)Power Consumption . . . . . . . . . . . . . . . .115 Vac, 50/60 Hz, 350W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .230 Vac, 50/60 Hz, 390W PMT200A-82015 . . . . . . . . . . . . . . . . .Summary alarm only Standard unit
Place a Bid!
|
|
|
Search
Categories
More related categories
 |
[home] [sitemap]
|