FLUKE SIGMAPACE 1000 EXTERNAL PACEMAKER ANALYZER
| Start Price |
USD 649.95 |
| Current Price |
USD 649.95 |
| Time Left |
- |
| Bid Count |
0 |
| Buy It Now Price |
- |
| Reserve Price |
- |
| Start Time |
Wednesday, September 24, 2008 |
| End Time |
Friday, October 24, 2008 |
| Location |
California |
|
See more about 'FLUKE SIGMAPACE 1000 EXTERNAL PACEMAKER ANALYZER'
|
Description
FLUKE SIGMAPACE 1000 EXTERNAL PACEMAKER ANALYZER This is a slightly used like new Fluke Sigmapace 1000 external pacemaker analyzer. Last calibration date Feb 2006 due Feb 2007. The SigmaPaceTM 1000 is a powerful handheld analyzer with a comprehensive range of test suites, measurement algorithms and test loads – as specified by the external pacemaker manufacturers – to fulfill your testing requirements both quickly and efficiently. Unique full-featured biomedical test product Tests for both transcutaneous and transvenous external pacemakers Full range of user-selectable measurement algorithms and test loads for external pacemakers Dual-channel signal acquisition for capturing synchronous AV-sequential pulse data Interactive pacemaker and ECG simulation with 5-lead output Large 21-character x 8-line alphanumeric LCD readout Exclusive readout "HOLD" function Exclusive SigmaPaceTM 1000 test features: DC static/dynamic leakage, and current drain Modes of Operation Manual Remote (via standard RS232 serial port) User Interface Display: - LCD readout - 21 characters X 8 lines - Brightness/viewing angle adjustment Keys: Eight push buttons (F-2, F-3 [UP arrow], F-4 [UP arrow], two DOWN arrows, ESCAPE, and ENTER) Transcutaneous Pacer Tests: Output Pulse Measurement Current: - Ranges: 4.00 mA to 9.99 mA; 10.0 mA to 99.9 mA; 100 mA to 250 mA - Accuracy: ± 2 % of reading or ± 50 µA (whichever is greater) Rate: - Ranges: 5.0 PPM to 99.9 PPM; 100 PPM to 300 PPM - Accuracy: ± 0.5 % of reading or ± 0.3 PPM (whichever is greater) Width: - Ranges: 1.00 mS to 9.99 mS; 10.0 mS to 99.9 mS - Accuracy: ± 0.5 % of reading or ± 14 µS (whichever is greater) Energy: - Ranges: 1 µJ to 999 µJ; 1 mJ to 999 mJ; 1.00 J to 1.99 J - Accuracy: 5 % of reading/computation Demand and Asynchronous Mode Tests Waveform (Physiological Simulation): - Normal sinus rhythm (NSR) - Complete P-QRS-T complex Amplitude: 1.0mVpeak (lead I) Modes of Operation: - Underdrive: NSR @ 85 % of pulse interval/rate - Overdrive: NSR @ 115 % of pulse interval/rate - Auxiliary Control: NSR adjustable in 1-BPM increments - Auxiliary Rate Range: Underdrive 10 BPM (min); overdrive 300 BPM (max) Active Outputs: 5-lead ECG; ventricular test load; high-level ECG jack Pacemaker Compatibility: - Pulse Rates: 30 to 200 PPM - Intended Types: Demand: VVI (pace and sense); async: VOO (pace) Amplitude Sensitivity Test Selections: R, S and T Waves - Rate: 30 to 200 PPM - Test Loads: (30) 50 Ω to 1550 Ω in 50-Ω steps Waveforms: Square (SQU); triangle (TRI); haversine (HSN); sine square (SSQ) Amplitude: - Range: 0.05 mVpeak to 5.0 mVpeak - Accuracy: ± 5 % of setting Resolution: 0.05-mV steps (0.05 to 0.95 mVpeak); 0.50-mV steps (1 to 5 mVpeak) Width: - Range: 0.15 mS to 300 mS - Accuracy: ± 5 % of setting - Selections: 50 - Resolution: 0.05-mS steps (0.15 to 0.95 mS); 1-mS steps (1 to 19 mS); 5-mS steps (20 to 95 mS) 25-mS steps (100 to 300 mS) Active Outputs: 5-lead ECG; ventricular test load; high-level ECG jack Pacemaker Compatibility: - Pulse Rates: 30 to 200 PPM - Intended Type: VVI (pace and sense) Noise Immunity/Line Frequency Test Waveform: Sine wave - Frequency: 50 and 60 Hz - Accuracy: 0.5 Hz Amplitude Testload Output: - Range: 0 (OFF) to 10 mVpeak-to-peak - Accuracy: ± 5 % of setting - Resolution: 0.5-mVpeak-to-peak steps - Settings: (30) 50 Ω to 1550 Ω ± 1 % 5-lead ECG Output: - Range: 0 (OFF) to 10 mVpeak-to-peak - Accuracy: ± 5 % of setting - Resolution: 0.50-mV steps - Reference: Lead I (RA to LA) Active Outputs: 5-lead ECG; ventricular test load Paced Refractory Period Test (PRP) Range: 20 mS to 500 mS - Accuracy: 5 % of reading or 1 mS (whichever is greater) Physiological Simulation: - Selection: Single pulse, R Wave, SSQ - Pulse Width: 40 mS Outputs: 5-lead ECG; ventricular test load Pacemaker Compatibility: - Pulse Rates: 30 to 200 BPM - Intended Type: VVI (pace and sense) Sensed Refractory Period Test (SRP) Range: 15 mS to 500 mS Accuracy: ± 5 % of reading or ± 1 mS (whichever is greater) Physiological Simulation: - Selection: Double pulse, R Wave, SSQ - Pulse Width: 40 mS - Amplitude: 1 mVpeak lead I Active Outputs: 5-lead ECG; ventricular test load Pacemaker Compatibility: - Pulse Rates: 30 to 200 BPM - Intended Type: VVI (pace and sense) Test Loads Transcutaneous Pacer: - Selections: (31) 50 Ω to 1550 Ω in 50-Ω steps - Accuracy: ± 1 % of selection - Power Rating: 5 W (average); 40 W (peak) @ 1000 Ω Input Defibrillation Protection: - Type: Internal spark gap Episode Limit: 5 pulses @ 360 J (10 seconds min between discharges) - Life Limit: 250 pulses @ 360 J Transvenous Pacer Tests: Output Pulse Measurement Current: - Ranges: 0.05 mA to .999 mA (available single channel only); 1.00 mA to 9.99 mA; 10 mA to 30 mA - Accuracy: ± 2 % of reading or ± 50 µA (whichever is greater) - Polarity Indicator: + or - Rate: - Ranges: 10.0 PPM to 99.9 PPM; 100 PPM to 999 PPM - Accuracy: ± 0.5 % or 0.3 PPM (whichever is greater) Width: - Ranges: 0.020 mS to .999 mS; 1.00 mS to 9.99 mS; 10.0 mS to 99.9 mS - Accuracy: 0.5 % or ± 14 µS (whichever is greater) - Resolution: ± 1 LSD or ± 4 µS (whichever is greater) Voltage: - Ranges: (available single channel only) 0.050 Vpeak to .999 Vpeak; 1.00 Vpeak to 9.99 Vpeak; 10 Vpeak to 30 Vpeak - Accuracy: ± 2 % of reading or ± 0.05 Vpeak (whichever is greater) - Polarity Indicator: + or - Energy: - Ranges: (available single channel only) 1 nJ to 999 nJ; 1 µJ to 999 µJ - Accuracy: ± 5 % of reading/computation Display Formats: Atrial channel only; ventricular channel only; both A + V channels AV Interval (Delay Time) Measurement Ranges: 10.0 mS to 99.9 mS; 100 mS to 999 mS Start Point: Atrial pulse leading edge Stop Point: Ventricular pulse leading edge Accuracy: 1 % of reading/computation Demand/Async Mode Tests Channels: Single and dual Waveform: Sine square (SSQ) Atrial Output: Simulated P Wave - Width: 30 mS - Amplitude: 2.0 mVpeak Vent Output: Simulated R Wave - Width: 40 mS - Amplitude: 2.5 mVpeak AV Interval: 90 mS (fixed) Interactive Simulated Rates: - Default Settings: Underdrive = NSR @ 85 % of pulse interval/rate; overdrive = NSR @ 115 % of pulse interval/rate - Manual: NSR simulations adjustable in 1-BPM increments - Limits: Underdrive (min) = 10 BPM; overdrive (max) = 300 BPM Output: Ventricular channel test load; atrial channel test load Pulse Rate: 30 to 200 PPM Intended Pacemaker Types: - Demand: VVI (V-channel pace and sense); AAI (A-channel pace and sense); DDD (dual-channel pace and sense) - Async/Continuous: VOO (V-channel pace and sense); AOO (A-channel pace and sense); DOO (dual-channel pace and sense) Amplitude Sensitivity Test Operation: Single-channel operation only (atrial or ventricular) Atrial Channel (Physiological Simulation): - Selection: P Wave - Rate: 30 to 120 BPM - Timing: Waveform delayed by 80 % of the pulse-to-pulse interval or 400 mS (whichever is shorter) - Active Output: Atrial test load Available Test Loads: 200 Ω, 500 Ω (default setting) and 1000 Ω ± 1 % Waveform Selections: Square (SQU); triangle (TRI); haversine (HSN); sine square (SSQ) (default setting); asymmetrical triangle (ISO) – fixed width: 2 mS rise time/13 mS fall time Sensitivity Waveform Amplitude: - Test Load Selection: 500 Ω (default setting) -- Range: 0.05 mVpeak to 50.0 mVpeak -- Accuracy: ± 5 % of setting --Resolution: 0.05 mVpeak (0.05 to 0.95 mVpeak); 0.50 mVpeak (1 to 50 mVpeak) - Test Load Selection: 200 Ω -- Range: 0.05 mVpeak to 20.0 mVpeak -- Accuracy: ± 5 % of setting -- Resolution: 0.05 mVpeak (0.05 to 0.95 mVpeak); 0.50 mVpeak (1 to 20 mVpeak) - Test Load Selection: 1000 Ω -- Range: 0.05 mVpeak to 100 mVpeak-to-peak -- Accuracy: ± 5 % of setting -- Resolution: 0.05 mVpeak (0.05 to 0.95 mVpeak); 0.50 mVpeak (1.0 to 49.5 mVpeak); 05.0 mVpeak (50 to 100 mVpeak) - Default Setting: 2.0 mVpeak Widths: - Range: 0.15 mS to 95.0 mS - Accuracy: ± 5 % of setting - Resolution: 0.05 mS (0.15 mS to 0.95 mS); 1 mS (1 mS to 19 mS); 5 mS (20 mS to 95 mS) Intended Pacemaker Types: AAI (atrial pace and sense) - Pulse Rates: 30 to 200 PPM Ventricular Channel (Physiological Simulation): - Selection: R Wave, S Wave and T Wave - Rate: 30 to 120 BPM - Timing: Waveform delayed from the ventricular demand pacemaker pulse by 80 % of the pulse-to-pulse interval or 400 mS (whichever is shorter) - Active Output: Selected ventricular test load Waveform Selections: Square (SQU); triangle (TRI); haversine (HSN); sine square (SSQ) (default setting); asymmetrical triangle (ISO) – fixed width: 2 mS rise time/13 mS fall time Available Test Load(s): 200 Ω, 500 Ω (default setting) and 1000 Ω ± 1 % Amplitude: - Pacer Load Selection: 500 Ω -- Range: 0.05 to 50.0 mVpeak -- Accuracy: ± 5 % of setting -- Resolution: 0.05 mVpeak (0.05 to 0.95 mVpeak); 0.50 mVpeak (1 to 50 mVpeak) - Pacer Load Selection: 200 Ω -- Range: 0.05 mVpeak to 20.0 mVpeak -- Accuracy: ± 5 % of setting -- Resolution: 0.05 mVpeak (0.05 to 0.95 mVpeak); 0.50 mVpeak (1 to 20 mVpeak) - Pacer Load Selection: 1000 Ω -- Range: 0.05 mVpeak to 100 mVpeak-to-peak -- Accuracy: ± 5 % of setting -- Resolution: 0.05 mVpeak (0.05 to 0. 95 mVpeak); 0.50 mVpeak (1.0 to 49.5 mVpeak); 05.0 mVpeak (50 to 100 mVpeak) - Default Setting: 2.5 mVpeak Widths: - Range: 0.15 mS to 300 mS - Accuracy: ± 5 % of setting - Resolution: 0.05 mS (0.15 to 0.95 mS); 1 mS (1 to 19 mS); 5 mS (20 mS to 95 mS); 25 mS (100 mS to 300 mS) Intended Pacemaker Type(s): VVI (atrial pace and sense only) - Pulse Rates: 30 to 200 PPM Noise Immunity Test Channels: Single, atrial or ventricular only Waveform: Sine wave Frequency: 50 and 60 Hz Accuracy: ± 0.5 Hz Active Output(s): Atrial- or ventricular-channel test load Output Selections: Atrial channel only; ventricular channel only ECG Signal: ECG signal can be added to the selected channel. Atrial: 1 mVpeak Ventricular: 1.5 mVpeak Noise Line Amplitude: - Pacer Load Selection: 500 Ω -- Range: 0 (OFF) to 100 mVpeak-to-peak -- Accuracy: ± 5 % of setting -- Resolution: 5-mVpeak-to-peak steps - Pacer Load Selection: 200 Ω -- Range: 0 (OFF) to 40 mVpeak-to-peak -- Accuracy: ± 5 % of setting -- Resolution: 5-mVpeak-to-peak steps - Pacer Load Selection: 1000 Ω -- Range: 0 (OFF) to 200 mVpeak-to-peak -- Accuracy: ± 5 % of setting -- Resolution: 5-mVpeak-to-peak steps Refractory Period Test (Atrial Channel) Test Selections: Paced refractory period; sensed refractory period Period: 20 to 500 mS Accuracy: ± 5 % of reading (or ± 1 mS, whichever is greater) Resolution: ± 1 LSD Physiological Simulation: - Selection: Square wave (default setting) - Atrial Channel: Simulated P Wave - Width: 1 mS - Amplitude: 20 mVpeak - Active Outputs: Atrial channel (4mm banana jacks) only Additional Waveform Selections: Square (SQU); triangle (TRI); haversine (HSN); sine square (SSQ); asymmetrical triangle (ISO) – fixed width: 2 mS rise time/13 mS fall time Amplitude: - Range: .05 mVpeak to 50.0 mVpeak - Accuracy: ± 5 % of setting - Resolution: 0.05 mVpeak (0.05 to 0.95 mVpeak); 0.50 mVpeak (1.0 to 49.5 mVpeak ) Width: - Range: 0.15 mS to 95.0 mS - Accuracy: ± 5 % of setting - Resolution: 0.05 mS (0.15 to 0.95 mS); 1 mS (1 to 19 mS); 5 mS (20 to 95 mS) Active Outputs: Atrial channel (4mm banana jacks) only Intended Pacemaker Types: AAI (atrial pace and sense only) Pacemaker Rates: 30 to 200 PPM Available Test Load: 500 Ω ± 1 % Refractory Period Test (Ventricular Channel) Test Selections: Paced refractory period; sensed refractory period Period: 20 to 500 mS Accuracy: ± 5 % of reading (or ± 1 mS, whichever is greater) Resolution: ± 1 LSD Display Format: 3 digits Physiological Simulation: - Selection: Square wave (default setting) - Ventricular Channel: Simulated R Wave - Width: 1 mS - Amplitude: 20 mVpeak - Active Outputs: Ventricular channel (4mm banana jacks) only Additional Waveform Selections: Square (SQU); triangle (TRI); haversine (HSN); sine square (SSQ); asymmetrical triangle (ISO) – fixed width: 2 mS rise time/13 mS fall time Amplitude: - Pacer Load Selection: 500 Ω -- Range: .05 mVpeak to 50.0 mVpeak -- Accuracy: ± 5 % of setting -- Resolution: 0.05 mVpeak (0.05 to 0.95 mVpeak); 0.50 mVpeak (1.0 to 49.5 mVpeak) - Default setting: 20 mVpeak Width: - Range: 0.15 mS to 300.0 mS - Accuracy: ± 5 % of setting - Resolution: 0.05 mS (0.15 to 0.95 mS); 1 mS (1 to 19 mS); 5 mS (20 to 95 mS); 25 mS (100 to 300 mS) - Default setting: 30 mS Intended Pacemaker Types: VVI Pacemaker Rates: 20 to 200 PPM DC Leakage Current Measurement Range: 00.1 µA to 99.9 µA Input Polarity: Positive and negative Resolution: 1 LSD (0.1 µA) Display Format: 3 digits Test Selections: - Static: Continuous (power OFF) - Dynamic: Gated (power ON) Test Load/Input Configurations: - Atrial+ and atrial- - Ventricular+ and ventricular– - Atrial+ and ventricular+ Baseline/Test Selection: 500 Ω Dynamic Test Gating Algorithm: Measurement made 400 mS prior to the pacemaker pulse leading edge; 16 measurements averaged at a 4 mS rate for a total of 64 mS Specified Applied Pacemaker Rate: 80 PPM Current Drain Test DC Current Ranges: 0.100 mA to 0.999 mA; 1.00 mA to 9.99 mA; 10.0 mA to 99.9 mA Polarity: Positive or negative Indicator: + or – symbol Resolution: ± 1 LSD Display Format: 3 digits plus decimal point Accuracy: ± 5 % of reading ± 10 µA Input DC Voltage: - Nominal: ± 9 V - Range: 5.0 V to 10.5 V - Input Protection: Short-circuit protection - Protection Type: Internal in-line fast-acting 1⁄2 A fuse Selectable Testloads: 200 Ω, 500 Ω, and 1000 Ω Battery Test Fixture: 9 V battery supply included, to facilitate connection of analyzer to recessed battery terminals within Medtronic 5388 and 5348 Temporary Pacemakers Test Loads Atrial Channel: - Selections: 200 Ω, 500 Ω, and 1000 Ω - Accuracy: ± 1 % of selection - Power Rating: 2 W Ventricular Channel: - Selections: 200 Ω, 500 Ω, and 1000 Ω - Accuracy: ± 1 % of selection - Power Rating: 2 W Tracking: Identical atrial and ventricular channel settings Input Defibrillation Protection: - Type: Internal spark gap - Episode Limit: 5 pulses @ 360 J (10 seconds min between discharges) - Life Limit: 250 pulses @ 360 J Long-Term Test Test Configuration: - Transvenous Pacer: Atrial or ventricular channel only - Transcutaneous Pacer: Ventricular channel - Pulse Count Range: 999,999 (max) - Rate: 2 % to 20 % (default setting, 10 %) - Amplitude: 2 % to 20 % (default setting, 10 %) - Test Time (max): 999:59:59 (hhh:mm:ss) - Maximum Error Count: 200 - Test Termination: Manual; or upon max error count - Testloads: 200 Ω, 500 Ω, and 1000 Ω Interactive Pacer ECG Simulation Simulation of demand, continuous, noncapture, and nonfunction patient -ECG activity Additional user -selectable parameters: - NSR Heart Rate: Asystole and 20 to 250 BPM (1-BPM steps) - NSR PR Interval: 0.05 to 0.30 s (6 settings) Pacemaker Capture/Threshold: - Transcutaneous: 10 to 250 mA (10-mA steps) - Transvenous: 1 to 25 mA (1-mA steps) General Specifications Serial Port: - Type: RS232 - Connector Type: DB-9 (male) - Baud Rates: 2400, 9600, and 19200 - Data Control: Xon/Xoff Power Requirements: - External battery charger source/power supply - 100 to 240 Vac, 50/60 Hz operation - Auto power-off feature during battery operation Battery Life: 20 hours (min) Environmental Specifications Temperature Range: - Operating: 15 °C to 35 °C (59 °F to 95 °F) - Storage: 0 °C to 50 °C (32 °F to 122 °F) Humidity Range: < 90 % noncondensing Dimensions Size: 8” L X 4” W X 2” H (approx) (203 mm L X 101 mm W X 50 mm H) Weight: 2 lb (approx) (0.90 kg) CE Mark User Safety: EMC: EN61326-1.1997 Conforms to: UL STD 3101-1 Certified to: CAN/USA STD C22.2 No.1010 ETL Listed Device has received FDA 510(k) clearance (on file) Photo shows the actual item for sale. "The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item." The purchaser will not hold the seller responsible for the appropriate or inappropriate use of this device either by the user or a third party or liable for any injuries or damages whether incidental or coincidental associated in anyway from the use of this device. PAYMENT OPTIONS: Invoice will be sent 24 hours after auction ends. If you did not received an invoice please feel free to contact us. Payment MUST be received no later than 7 calendar days from end of auction and must be received/cleared before item can be shipped. Please inform us if you are bidding on more than one item so we can combine shipping cost and send only one invoice. If no payments are made or no communication about payment being made within 7 days, we will report listing as UNPAID. U.S. Bidders: We accpet Paypal and Money Order Only. Payment made with Money Order must be postmarked within 7 days after auction ends. Please don't forget to write auction number. International Bidders: We accept Paypal Only. SHIPPING: FAST SHIPPING USING USPS PRIORITY MAIL Delivery comfirmation is provided on all U.S. shipments. Most orders are shipped within 24 hours after payment is received/cleared. Shipping insurance is optional. We are not responsible for merchandise lost, stolen or damaged during shipment. For U.S. Bidders: USPS Priority Mail shipping and handling. For International Bidders: Please e-mail us your country name for a shipping and handling quote. LAMBO TECHNOLOGIES, Medical Equipment Reseller, California
Place a Bid!
|
|
|
Search
 |
[home] [sitemap]
|