Cryogenic Superfluid Helium Liquefaction System

Cryogenic Superfluid Helium Liquefaction System
Capable of producing temperatures as low as 1 Kelvin
Cryogenic Superfluid Helium Liquefaction System
Start Price USD 895,000.00
Current Price USD 895,000.00
Time Left -
Bid Count 0
Buy It Now Price -
Reserve Price -
Start Time Wednesday, August 27, 2008
End Time Saturday, September 06, 2008
Location Spring, Texas

See more about 'Cryogenic Superfluid Helium Liquefaction System '

Description
***We have 2 universities that would love to acquire this system but don't currently have the funds. Are you interested in making a tax deductible donation directly to the university in order for them to be able to purchase this system? Does your company have the matching funds program? Call our office at 360-459-1395 regarding any interest in funding this system on behalf of the university of your choice.   Cryogenic Superfluid Helium Liquefaction System Capable of producing temperatures as low as 1 Kelvin, near absolute zero This system is a Cryogenics Consultants, Inc Model 300 JPS Cold Box with Wet Engine Module providing refrigeration capacities up to 400 watts and liquefaction rates up to 100 liters per hour. The Helium refrigerator / liquefier system includes: 400 HP Sullair compressor 125 Ton Delta cooling tower1500 Liter helium dewarTwo 12,000 Gallon helium gas storage vesselsTwo 1000 Gallon suction buffer vesselsA 3000 Gallon liquid nitrogen storage tank25 HP Recovery  compressor  All interconnecting stainless steel piping and vacuum jacketed transfer lines The super fluid helium portion of the system includes: Heat exchanger moduleThree Beach Russ vacuum pumps with boostersFlanged bellows and valvesInterconnecting stainless steel piping The entire system is currently installed in an air conditioned building and operational.Operator training could be conducted prior to removing the system.Helium refrigerator / liquefier system specs: Cold BoxThe helium liquefier / refrigerator cold box is a Cryogenic Consultants, Inc. CCI Model 300 JPS with the optional wet engine module. The cold box was manufactured by Meyer Tool & Manufacturing Incorporated, Oak Lawn, Illinois. The cold box is designed to produce 400 watts refrigeration at 4.5 K or 100 liters of liquid helium per hour from warm helium gas. Liquid nitrogen is supplied to the cold box as a pre-coolant. Liquid nitrogen consumption is rated at 0.7 liters of liquid nitrogen per liter of liquid helium produced. Photo 1 - CCI Cold Box The ‘cold box' is a super insulated, vacuum jacketed component containing the heat exchangers, extended stem cryogenic valves, expansion (JT) valve and a piston type expansion engine. Helium gas, compressed to 265 PSIG, enters the cold box at near room temperature and is cooled with liquid nitrogen and low pressure helium gas. The high pressure helium is further cooled by the cold helium gas exiting the piston expansion engine. This low press cold gas is produced when a portion of the high pressure gas stream expands in the cylinder of the "piston type" expansion engine. The remaining high pressure helium gas travels to a JT expansion valve or a wet expansion engine where the temperature of the gas is reduced to the liquefaction temperature of helium. The liquefied helium exiting the JT valve or wet expansion engine is transferred to the liquid helium dewar through bayoneted vacuum jacketed transfer tubes. A small portion of the helium returns as cold helium gas to the cold box to be used to cool the high pressure helium gas stream.Photo 1 shows the cold box as manufactured. Modifications to the instrument panel on the cold box can be seen in Photo 2. The changes include moving the gas expander speed control box to a location above the control panel. An electrical enclosure was installed in place of the speed control box to house three PID controllers. Photo 2 - Modified Control Panel ControlsThe system is controlled with pneumatic actuators and controllers. However the helium suction pressure incorporates a duel output PID controller and two I/P transducer controlled pneumatic actuated valves to supply helium make up gas or remove excess helium in the suction manifold. A common problem associated with pneumatic controls is the internal corrosion created by moisture carried in with the instrument air. Rather than using compressed air, this system has been operated from the boil off nitrogen gas created in the liquid nitrogen storage tank. As a result, the controllers and actuators are clean and corrosion free. Helium Gas Management RackThe helium gas management rack consists of three pneumatically controlled valves used to maintain compressor discharge and suction pressures. The valves are compressor discharge or "by-pass valve", suction make up and suction withdraw valves. Photo 3 - Gas Management Rack   Compressor Photo 4 - Sullair Compressor The helium compressor is an oil flooded screw compressor Sullair Model C20LA 704-48-400 HP. The compressor is driven by a 480 Volt AC electric motor with a rating of 400 horse power. The screw compressor has a built in slide-valve to match compressor capacity with refrigeration load thus permit efficient system operation.In photo 4, the electric motor is the gray unit located on the right side of the vertical oil knock out tank. Photo 5 - Recovery Compressor Recovery compressorA 25 HP Dunham Bush Compressor, seen in Photo 5, stores the helium boil-off cryostats when the Sullair compressor is off. The small compressor can be used to circulate ambient temperature helium to warm cryogenic devices.A 25 HP Dunham Bush Compressor, seen in Photo 5, sends helium boil-off gas to the storage vessels when the Sullair compressor is off. The small compressor can be used to circulate ambient temperature helium to warm cryogenic devices. Compressor Oil Purifier The DuPont LB 170X oil is processed before installation into the Sullair compressor. The process, seen in Photo 6, heats the compressor oil in the two vertical tanks while under vacuum to remove moisture or chemicals that may separate from the oil during compressor operation. The oil in the two tanks can be pressured and sent directly into the oil knock out tank as needed. Photo 6 - Compressor Oil Purifier   Cooling Tower The Sullair and Dunham Bush Compressors are water cooled by a 125 Ton Delta Cooling Tower. The water is circulated by a 300 gallon per minute centrifugal pump through a PVC piping system. The tower shell is made of seamless polyethylene (LDPE). The wet decking and drift eliminator are constructed from a spiral, one piece ABS. The blower fan motor is a 15 HP, 460 volt, 60 Hz., 3 phase, ODP type.In Photo 7, the black Delta Cooling Tower can be seen located in front of the helium gas storage tanks. The squirrel cage type fan can be seen on the left side of the tower body. The venting air flows upward through the tower. The water make up valve for the tower is located in the gray box to the right of the tower body. The make up water valve provided by the manufacturer of the tower was located inside the tower. Problems associated with this location resulted in the relocation and redesign of the make up water system. Photo 7 - Delta Cooling Tower with Helium Vessels in Background   Storage   Helium Gas StorageThe helium gas is stored in two horizontal 12,000 gallon pressure vessels as shown in Photo 8. The tank dimensions are 84 inches outside diameter by 45 feet 2 9/16 inches long and has weld on tank saddles. Each vessel was manufactured for a working pressure range of ‘full vacuum' to 250 PSIG at a temperature of 125°F. The weight of each tank is 21,000 pounds. The volume of helium gas in each pressure vessel when at rated pressure will produce 1000 liters of liquid helium. Suction Buffer TanksIn Photo 8 the two 1000 gallon pressure vessels used as suction pressure buffer tanks can be seen mounted on top of the 12,000 gallon tank on the left. The mounting platforms were included in the design of the tank and installed by the tank manufacturer. Photo 8 - Helium Gas Storage Tanks   Liquid Nitrogen Storage Photo 10 - Liquid Nitrogen Filter Photo 9 - Liquid Nitrogen Tank A 3,000 gallon liquid nitrogen tank provides pre-cooling to the refrigerator and cooling to the thermal shield in the 1500 liter helium dewar. The LN2 tank is connected to the cryogenic test area by a vacuum insulated transfer line. The nitrogen gas is used for instrument air and also available for pump down and purge of insulating vacuum spaces.In Photo 9, the liquid nitrogen vaporizer can be seen mounted to the liquid nitrogen tank.In Photo 10, the vacuum jacketed liquid nitrogen filter is used to remove moisture introduced by supplier during liquid nitrogen filling of the storage tank.The liquid nitrogen fill pedestal, seen in Photo 11, is located at the curb side for ease of refilling. Photo 12 shows the liquid nitrogen pedestal located at the liquid nitrogen tank.   Photo 12 Photo 11 Photo 13 - Liquid Helium Tank   Liquid Helium StorageA 1500 liter liquid helium dewar stores and distributes the liquid helium through two flow control valves equipped with bayoneted ports The valves are a low heat leak design utilizing springs to close and a stainless steel pull rod to open. The liquid helium valves are positioned with a Foxboro / Jordan Model VA-1110 electric actuator. The valve position is determined by a 4-20 ma signal from a temperature controller or liquid level controller.The liquid helium dewar contains liquid nitrogen reservoir to provide coolant to a thermal shield. Other Components:   Photo 14 - CVI Vacuum Pump Out Vacuum jacketed pipingAll cryogens are transferred between components through vacuum jacketed, superinsulated piping. Each vacuum space is equipped with a DV-6 thermocouple vacuum gauge and a CVI pump out / vacuum relief valve as shown in Photo 14. Connecting piping and fittingsAll high and low pressure helium piping is fabricated from 304 stainless steel pipe or tubing. Written Safety PlanLockout / Tag out Procedure - contains a detailed lockout / tag out procedure including flow drawings. Photo 16 shows isolation valve locked out. Photo 16 - Valve Locked Out Photo 15 - Lockout / Tag Out Center   Super fluid helium specs:   The super fluid helium system consists of a heat exchanger module, three vacuum pumping systems and all interconnecting stainless steel piping, flanged bellows and valves. The three vacuum pumping systems are used to attain a vacuum of 12 torr above a reservoir of liquid helium in the heat exchanger module. The helium gas is discharged from the vacuum pump manifold back into the compressor suction. To prevent blending of oils, both the vacuum pumping systems and helium compressor contain the same type of oil.The vacuum pumping systems are Beach - Russ Model Number 5524-750 which consists of a Beach - Russ Model 750 mechanical pump with a 900 CFM pumping capacity and M-D Model 5524 - 90L2 mechanical booster with a 2,700 CFM capacity. Each pumping system contains an inlet and outlet bellows and isolation valves. The inlet valve is controlled remotely by a Raymond Control System Actuator Model 4060-DA with pneumatic positioner. Total operating time for the pumping systems ranges from 1712.5 to 2107.3 hours.The vacuum pumps and heat exchanger are connected by a 10 inch schedule 10 stainless steel piping. The exhaust heater connecting the system to the compressor suction is 6 inch stainless steel pipe.     Beach Russ vacuum systems are connected in parallel with stainless steel piping at both inlet and discharge side. Each pumping system is controlled individually by a inlet valve with positioner.Total operating hours for each pump from right to left is 1712.5 hours, 1812.5 hours and 2107.1 hours.Since commissioning, the mechanical pumps have only operated with Ucon LB 170 X synthetic oil. Each electric motor has a fused electrical disconnect that can be locked out as per standard OSHA "lockout / tagout procedure". Each vacuum system has an inlet and outlet bellows with isolation valve on the outlet and a valve with controller / positioner on the inlet. Blower Motor Plate - 25 HP Mechanical Pump Motor Plate - 50 HP Beach Russ Model Number 5524-750Model 750 Mechanical at 900 CFMModel 90L2 Mechanical booster at 2,700 CFM Mechanical pump motor with belt guard: belt guard is bolted to floor and is easily removed with attached handles. MD Blower and motor A 10 inch Sch 10 pipe serves as an inlet header connecting the three pumps. Each end of the horizontal run of 10 inch pipe contains a 150 pound raised face flange. The combined pumping speed of the three pumps is controlled by a 10 inch vacuum valve with controller / positioner. The discharge side is connected with 6 inch Sch 10 pipe with a 150 pound raised face flange on one end of the horizontal run. BR Mechanical pump   Auction Terms:Invoices will be providedSubject to prior saleShipping preparation and charges are responsibility of the purchaserAs is, Where is F.O.B. The Woodlands, Tx. 77381Deinstallation and shipping charges will be incurred by purchaser; please inquire before bidding    Contact:  E-mail:  cbrown@cdproservices.com C & D Professional ServicesPhone: 360-459-1395www.cdproservices.com C & D Services statement regarding the equipment we sell: Information regarding the history and condition of the equipment we offer has been included exactly as it has been received in the description of the property. Normally, the property has not been operated or tested by C & D to determine it's fitness for a purpose.  The Property is sold and conveyed "AS IS, WHERE IS," and without representation or warranty. The seller hereby expressly disclaims all warranties, either express or implied, including an implied warranty of merchantability or fitness for a purpose

Place a Bid!

More lots See also lots
  • John Deere 650J Dozer Forestry package 1400 hours
  • GAS STATION WITH C-STORE
  • Nativity Museum in Branson Missouri
  • New AmerDuro Steel Building 80x200x14 Metal Buildings
  • INVESTMENT OPPORTUNITY !! US Patent Tire Valve Stem Cap
  • LUME 1 ONE Lumenis IPL Yag Hair Removal Laser Skin
  • WEBB STEEL PLATE ROLLER - Roladora de Placa de Acero
  • ***1000 KW/1250 KVA AMD INDUSTRIAL DIESEL GENERATORS***

  • Search
     

    Categories
    Fuel & Energy
    Other
    Printing & Graphic Arts
    Office
    Packing & Shipping
    Business & Industrial
    Retail & Services
    Restaurant & Catering
    Healthcare, Lab & Life Science
    Manufacturing & Metalworking
    Construction
    Businesses for Sale
    Agriculture & Forestry
    Electrical & Test Equipment
    Industrial Supply & MRO

    More related categories
    Dry Cleaning & Laundromat
    Buildings, Modular & Pre-Fab
    Bar & Beverage Equipment
    Wholesale Lots
    Woodworking

     
    eBay Developers Program Member

     [home] [sitemap]
    12/1/2008 4:31:29 PM